Bioanalysis ; 14(6): 325-340, 2022 Mar.
Article in English | MEDLINE | ID: covidwho-1726396

ABSTRACT

Background: With the spread of COVID-19, anti-SARS-CoV-2 antibody tests have been utilized. Herein we evaluated the analytical performance of anti-SARS-CoV-2 antibody test kits using a new reference standard prepared from COVID-19 patient sera. Methods: Fifty-seven kits in total (16 immunochromatography types, 11 ELISA types and 30 types for automated analyzers) were examined. By measuring serially diluted reference standards, the maximum dilution factor showing a positive result and its precision were investigated. Results: The measured cut-off titers varied largely depending on the antibody kit; however, the variability was small, with the titers obtained by each kit being within twofold in most cases. Conclusion: The current results suggest that a suitable kit should be selected depending on the intended purpose.


Subject(s)
COVID-19 Serological Testing/methods , Reagent Kits, Diagnostic , Antibodies, Viral/blood , Automation, Laboratory , COVID-19 Serological Testing/instrumentation , COVID-19 Serological Testing/standards , Enzyme-Linked Immunosorbent Assay/instrumentation , Enzyme-Linked Immunosorbent Assay/methods , Humans , Immunoglobulin G/blood , Japan , SARS-CoV-2/immunology
3.
Microbiol Spectr ; 10(1): e0161421, 2022 02 23.
Article in English | MEDLINE | ID: covidwho-1691406

ABSTRACT

The antigen-based rapid diagnostic test (Ag-RDT) using saliva specimens is fast, noninvasive, and suitable for SARS-CoV-2 self-testing, unlike nasopharyngeal swab (NPS) testing. We evaluated a novel Beanguard gargle (BG)-based virus collection method that can be applied to Ag-RDT as an alternative to the current RT-PCR with an NPS for early diagnosis of COVID-19. This clinical trial comprised 102 COVID-19-positive patients hospitalized after a governmental screening process and 100 healthy individuals. Paired NPS and BG-based saliva specimens from COVID-19 patients and healthy individuals were analyzed using NPS-RT-PCR, BG-RT-PCR, and BG-Ag-RDTs, whose diagnostic performance for detecting SARS-CoV-2 was compared. BG-Ag-RDTs showed high sensitivity (97.8%) and specificity (100%) in 45 patients within 6 days of illness and detected all cases of SARS-CoV-2 Alpha and Delta variants. In 11 asymptomatic active COVID-19 cases, both BG-Ag-RDTs and BG-RT-PCR showed sensitivities and specificities of 100%. Sensitivities of BG-Ag-RDT and BG-RT-PCR toward salivary viral detection were highly concordant, with no discrimination between symptomatic (97.0%), asymptomatic (100%), or SARS-CoV-2 variant (100%) cases. The intermolecular interactions between SARS-CoV-2 spike proteins and truncated canavalin, an active ingredient from the bean extract (BE), were observed in terms of physicochemical properties. The detachment of the SARS-CoV-2 receptor-binding domain from hACE2 increased as the BE concentration increased, allowing the release of the virus from hACE2 for early diagnosis. Using BG-based saliva specimens remarkably enhances the Ag-RDT diagnostic performance as an alternative to NPS and enables noninvasive, rapid, and accurate COVID-19 self-testing and mass screening, supporting efficient COVID-19 management. IMPORTANCE An Ag-RDT is less likely to be accepted as an initial test method for early diagnosis owing to its low sensitivity. However, our self-collection method, Ag-RDT using BG-based saliva specimens, showed significantly enhanced detection sensitivity and specificity toward SARS-CoV-2 including the Alpha and Delta variants in all patients tested within 6 days of illness. The method represents an attractive alternative to nasopharyngeal swabs for the early diagnosis of symptomatic and asymptomatic COVID-19 cases. The evidence suggests that the method could have a potential for mass screening and monitoring of COVID-19 cases.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Saliva/virology , Adult , Aged , Aged, 80 and over , COVID-19/virology , COVID-19 Nucleic Acid Testing , COVID-19 Serological Testing/instrumentation , Female , Humans , Male , Middle Aged , Nasopharynx/virology , Republic of Korea , SARS-CoV-2/genetics , SARS-CoV-2/immunology , Sensitivity and Specificity , Young Adult
4.
Anal Bioanal Chem ; 414(8): 2607-2618, 2022 Mar.
Article in English | MEDLINE | ID: covidwho-1653432

ABSTRACT

The lateral flow assay (LFA) is one of the most popular technologies on the point-of-care diagnostics market due to its low cost and ease of use, with applications ranging from pregnancy to environmental toxins to infectious disease. While the use of these tests is relatively straightforward, significant development time and effort are required to create tests that are both sensitive and specific. Workflows to guide the LFA development process exist but moving from target selection to an LFA that is ready for field testing can be labor intensive, resource heavy, and time consuming. To reduce the cost and the duration of the LFA development process, we introduce a novel development platform centered on the flexibility, speed, and throughput of an automated robotic liquid handling system. The system comprises LFA-specific hardware and software that enable large optimization experiments with discrete and continuous variables such as antibody pair selection or reagent concentration. Initial validation of the platform was demonstrated during development of a malaria LFA but was readily expanded to encompass development of SARS-CoV-2 and Mycobacterium tuberculosis LFAs. The validity of the platform, where optimization experiments are run directly on LFAs rather than in solution, was based on a direct comparison between the robotic system and a more traditional ELISA-like method. By minimizing hands-on time, maximizing experiment size, and enabling improved reproducibility, the robotic system improved the quality and quantity of LFA assay development efforts.


Subject(s)
COVID-19/diagnosis , Immunoassay/instrumentation , Malaria/diagnosis , Point-of-Care Testing , Tuberculosis/diagnosis , COVID-19 Serological Testing/economics , COVID-19 Serological Testing/instrumentation , Equipment Design , Humans , Immunoassay/economics , Mycobacterium tuberculosis/isolation & purification , Plasmodium/isolation & purification , Point-of-Care Testing/economics , Reproducibility of Results , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Time Factors
5.
PLoS One ; 16(3): e0247797, 2021.
Article in English | MEDLINE | ID: covidwho-1605332

ABSTRACT

Since the initial identification of the novel coronavirus SARS-CoV-2 in December of 2019, researchers have raced to understand its pathogenesis and begun devising vaccine and treatment strategies. An accurate understanding of the body's temporal immune response against SARS-CoV-2 is paramount to successful vaccine development and disease progression monitoring. To provide insight into the antibody response against SARS-CoV-2, plasma samples from 181 PCR-confirmed COVID-19 patients collected at various timepoints post-symptom onset (PSO) were tested for the presence of anti-SARS-CoV-2 IgM and IgG antibodies via lateral flow. Additionally, 21 donors were tracked over time to elucidate patient-specific immune responses. We found sustained levels of anti-SARS-CoV-2 antibodies past 130 days PSO, with 99% positivity observed at 31-60 days PSO. By 61-90 days PSO, the percentage of IgM-/IgG+ results were nearly equal to that of IgM+/IgG+ results, demonstrating a shift in the immune response with a decrease in IgM antibody levels. Results from this study not only provide evidence that the antibody response to COVID-19 can persist for over 4 months, but also demonstrates the ability of Easy Check™ to monitor seroconversion and antibody response of patients. Easy Check was sufficiently sensitive to detect antibodies in patient samples as early as 1-4 days PSO with 86% positivity observed at 5-7 days PSO. Further studies are required to determine the longevity and efficacy of anti-SARS-CoV-2 antibodies, and whether they are protective against re-infection.


Subject(s)
Antibodies, Viral/blood , COVID-19/blood , Immunoglobulin G/blood , Immunoglobulin M/blood , SARS-CoV-2/immunology , Adolescent , Adult , Aged , Aged, 80 and over , Antibodies, Viral/immunology , COVID-19/immunology , COVID-19 Serological Testing/instrumentation , COVID-19 Serological Testing/methods , Equipment Design , Female , Humans , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Longitudinal Studies , Male , Middle Aged , SARS-CoV-2/isolation & purification , Young Adult
6.
J Nanobiotechnology ; 20(1): 6, 2022 Jan 04.
Article in English | MEDLINE | ID: covidwho-1608546

ABSTRACT

BACKGROUND: Gold nanoparticles (AuNPs) have been widely used in local surface plasmon resonance (LSPR) immunoassays for biomolecule sensing, which is primarily based on two conventional methods: absorption spectra analysis and colorimetry. The low figure of merit (FoM) of the LSPR and high-concentration AuNP requirement restrict their limit of detection (LOD), which is approximately ng to µg mL-1 in antibody detection if there is no other signal or analyte amplification. Improvements in sensitivity have been slow in recent for a long time, and pushing the boundary of the current LOD is a great challenge of current LSPR immunoassays in biosensing. RESULTS: In this work, we developed spectral image contrast-based flow digital nanoplasmon-metry (Flow DiNM) to push the LOD boundary. Comparing the scattering image brightness of AuNPs in two neighboring wavelength bands near the LSPR peak, the peak shift signal is strongly amplified and quickly detected. Introducing digital analysis, the Flow DiNM provides an ultrahigh signal-to-noise ratio and has a lower sample volume requirement. Compared to the conventional analog LSPR immunoassay, Flow DiNM for anti-BSA detection in pure samples has an LOD as low as 1 pg mL-1 within only a 15-min detection time and 500 µL sample volume. Antibody assays against spike proteins of SARS-CoV-2 in artificial saliva that contained various proteins were also conducted to validate the detection of Flow DiNM in complicated samples. Flow DiNM shows significant discrimination in detection with an LOD of 10 pg mL-1 and a broad dynamic detection range of five orders of magnitude. CONCLUSION: Together with the quick readout time and simple operation, this work clearly demonstrated the high sensitivity and selectivity of the developed Flow DiNM in rapid antibody detection. Spectral image contrast and digital analysis further provide a new generation of LSPR immunoassay with AuNPs.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Surface Plasmon Resonance/methods , Antibodies, Viral/immunology , COVID-19/immunology , COVID-19 Serological Testing/instrumentation , Equipment Design , Gold/chemistry , Humans , Immunoassay/instrumentation , Immunoassay/methods , Metal Nanoparticles/chemistry , SARS-CoV-2/immunology , Saliva/virology , Spike Glycoprotein, Coronavirus/immunology , Surface Plasmon Resonance/instrumentation
7.
Bioengineered ; 13(1): 876-883, 2022 01.
Article in English | MEDLINE | ID: covidwho-1585254

ABSTRACT

This research has developed a method for rapid detection of SARS-CoV-2 N protein on a paper-based microfluidic chip. The chitosan-glutaraldehyde cross-linking method is used to fix the coated antibody, and the sandwich enzyme-linked immunosorbent method is used to achieve the specific detection of the target antigen. The system studied the influence of coating antibody concentration and enzyme-labeled antibody concentration on target antigen detection. According to the average gray value measured under different N protein concentrations, the standard curve of the method was established and the sensitivity was tested, and its linear regression was obtained. The equation is y = 9.8286x+137.6, R2 = 0.9772 > 0.90, which shows a high degree of fit. When the concentration of coating antibody and enzyme-labeled antibody were 1 µg/mL and 2 µg/mL, P > 0.05, the difference was not statistically significant, so the lower concentration of 1 µg/mL was chosen as the coating antibody concentration. The results show that the minimum concentration of N protein that can be detected by this method is 8 µg/mL, and the minimum concentration of coating antibody and enzyme-labeled antibody is 1 µg/mL, which has the characteristics of high sensitivity and good repeatability.


Subject(s)
Antigens, Viral/analysis , COVID-19 Serological Testing/instrumentation , Coronavirus Nucleocapsid Proteins/analysis , Coronavirus Nucleocapsid Proteins/immunology , Lab-On-A-Chip Devices , SARS-CoV-2/chemistry , SARS-CoV-2/immunology , Antibodies, Viral/immunology , Biomedical Engineering , COVID-19/diagnosis , COVID-19/immunology , COVID-19/virology , COVID-19 Serological Testing/methods , COVID-19 Serological Testing/standards , Coronavirus Nucleocapsid Proteins/standards , Enzyme-Linked Immunosorbent Assay/instrumentation , Enzyme-Linked Immunosorbent Assay/methods , Enzyme-Linked Immunosorbent Assay/standards , Humans , Lab-On-A-Chip Devices/standards , Lab-On-A-Chip Devices/statistics & numerical data , Microchip Analytical Procedures/methods , Microchip Analytical Procedures/standards , Microchip Analytical Procedures/statistics & numerical data , Paper , Phosphoproteins/analysis , Phosphoproteins/immunology , Phosphoproteins/standards
8.
J Med Virol ; 94(4): 1633-1640, 2022 04.
Article in English | MEDLINE | ID: covidwho-1568204

ABSTRACT

The coronavirus disease 2019 (COVID-19) is outbreaking all over the world. To help fight this disease, it is necessary to establish an effective and rapid detection method. The nucleocapsid (N) protein of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is involved in viral replication, assembly, and immune regulation and plays an important role in the viral life cycle. Moreover, the N protein also could be a diagnostic factor and potential drug target. Therefore, by synthesizing the N gene sequence of SARS-CoV-2, constructing the pET-28a (+)-N recombinant plasmid, we expressed the N protein in Escherichia coli and obtained 15 monoclonal antibody (mAbs) against SARS-CoV-2-N protein by the hybridomas and ascites, then an immunochromatographic test strip method detecting N antigen was established. In this study, we obtained 14 high-titer and high-specificity monoclonal antibodies, and the test strips exclusively react with the SARS-CoV-2-N protein and no cross-reactivity with other coronavirus and also recognize the recombinant N protein of Delta (B.1.617.2) variant. These mAbs can be used for the early and rapid diagnosis of SARS-CoV-2 infection through serological antigen.


Subject(s)
Antibodies, Monoclonal/immunology , COVID-19 Serological Testing/instrumentation , Coronavirus Nucleocapsid Proteins/immunology , SARS-CoV-2/isolation & purification , Animals , COVID-19/blood , COVID-19/diagnosis , COVID-19 Serological Testing/methods , Coronavirus Nucleocapsid Proteins/blood , Coronavirus Nucleocapsid Proteins/genetics , Humans , Immunoassay , Mice , Mutation , Phosphoproteins/blood , Phosphoproteins/genetics , Phosphoproteins/immunology , Recombinant Proteins/genetics , Recombinant Proteins/immunology , SARS-CoV-2/genetics , SARS-CoV-2/immunology , Sensitivity and Specificity
9.
Anal Bioanal Chem ; 414(3): 1313-1322, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1506326

ABSTRACT

Among the deadliest pandemics in history, coronavirus disease 2019 (COVID-19) has wreaked havoc on human lives, economies and public health systems worldwide. To temper its effects, diagnostic methods that are simple, rapid, inexpensive, accurate, selective and sensitive continue to be necessary. In our study, we developed an electrochemical biosensing platform based on gold clusters, mercaptoethanol, the spike protein of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) antigen and bovine serum albumin-modified glassy carbon electrode able to detect the SARS-CoV-2 spike antibody. Moreover, during the detection of the SARS-CoV-2 spike antibody in spiked-real samples, the anodic signal of the produced biosensor at 0.85 V decreased as the amount of the SARS-CoV-2 spike antibody increased. Meanwhile, the recovery and relative standard deviation values for saliva and oropharyngeal swab samples were 97.73% and 3.35% and 102.43% and 4.63%, respectively. In 35 min, the biosensing platform could detect 0.03 fg/mL of the SARS-CoV-2 spike antibody in synthetic media and spiked-saliva or -oropharyngeal swab samples. The method thus issues a linear response to the SARS-CoV-2 spike antibody from 0.1 fg/mL to 10 pg/mL. The cross-reactivity studies with spike antigens of Middle East respiratory syndrome-coronavirus and influenza A and the antigen of pneumonia confirmed the excellent selectivity of the proposed method. The developed method was compared with the lateral flow immunoassay method in terms of sensitivity and it was found to be approximately 109 times more sensitive. Biosensing mechanism of the platform to the SARS-CoV-2 spike antibody.


Subject(s)
Antibodies, Viral/analysis , COVID-19 Serological Testing/instrumentation , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Spike Glycoprotein, Coronavirus/analysis , Antibodies, Viral/immunology , Biosensing Techniques/instrumentation , COVID-19/immunology , Electrochemical Techniques/instrumentation , Equipment Design , Humans , Hydrogen Bonding , Models, Molecular , SARS-CoV-2/immunology , Saliva/virology , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/immunology
10.
J Clin Lab Anal ; 35(12): e24091, 2021 Dec.
Article in English | MEDLINE | ID: covidwho-1499275

ABSTRACT

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a highly infectious and concealed virus that causes pneumonia, severe acute respiratory syndrome, and even death. Although the epidemic has been controlled since the development of vaccines and quarantine measures, many people are still infected, particularly in third-world countries. Several methods have been developed for detection of SARS-CoV-2, but owing to its price and efficiency, the immune strip could be a better method for the third-world countries. METHODS: In this study, two antibodies were linked to latex microspheres, using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride and N-hydroxysuccinimide, as the bridge to decrease the cost further and improve the detection performance. The specificity of the lateral flow immunoassay strip (LFIA) was tested by several common viruses and respiratory bacterial infections. Besides, the reproducibility and stability of the LFIAs were tested on the same batch of test strips. Under optimal conditions, the sensitivity of LFIA was determined by testing different dilutions of the positive specimens. RESULTS: The proposed LFIAs were highly specific, and the limit of detection was as low as 25 ng/mL for SARS-CoV-2 antigens. The clinical applicability was evaluated with 659 samples (230 positive and 429 negative samples) by using both LFIA and rRT-PCR. Youden's index (J) was used to assess the performance of these diagnostic tests. The sensitivity and specificity were 98.22% and 97.93%, respectively, and J is 0.9615. The sensitivity and specificity were 98.22% and 97.93%, respectively, and J is 0.9615. In addition, the consistency of our proposed LFIA was analyzed using Cohen's kappa coefficient (κ = 0.9620). CONCLUSION: We found disease stage, age, gender, and clinical manifestations have only a slight influence on the diagnosis. Therefore, the lateral flow immunoassay SARS-CoV-2 antigen test strip is suitable for point-of-care detection and provides a great application for SARS-CoV-2 epidemic control in the third-world countries.


Subject(s)
Antigens, Viral/analysis , COVID-19 Serological Testing/methods , Immunoassay/methods , COVID-19 Serological Testing/instrumentation , Carbodiimides/chemistry , Humans , Immunoassay/instrumentation , Latex/chemistry , Methylamines/chemistry , Microscopy, Electron, Scanning , Microspheres , Point-of-Care Systems , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/immunology , Sensitivity and Specificity , Succinimides/chemistry
11.
Sci Rep ; 11(1): 20143, 2021 10 11.
Article in English | MEDLINE | ID: covidwho-1462040

ABSTRACT

Rapid, high-throughput diagnostic tests are essential to decelerate the spread of the novel coronavirus disease 2019 (COVID-19) pandemic. While RT-PCR tests performed in centralized laboratories remain the gold standard, rapid point-of-care antigen tests might provide faster results. However, they are associated with markedly reduced sensitivity. Bedside breath gas analysis of volatile organic compounds detected by ion mobility spectrometry (IMS) may enable a quick and sensitive point-of-care testing alternative. In this proof-of-concept study, we investigated whether gas analysis by IMS can discriminate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from other respiratory viruses in an experimental set-up. Repeated gas analyses of air samples collected from the headspace of virus-infected in vitro cultures were performed for 5 days. A three-step decision tree using the intensities of four spectrometry peaks correlating to unidentified volatile organic compounds allowed the correct classification of SARS-CoV-2, human coronavirus-NL63, and influenza A virus H1N1 without misassignment when the calculation was performed with data 3 days post infection. The forward selection assignment model allowed the identification of SARS-CoV-2 with high sensitivity and specificity, with only one of 231 measurements (0.43%) being misclassified. Thus, volatile organic compound analysis by IMS allows highly accurate differentiation of SARS-CoV-2 from other respiratory viruses in an experimental set-up, supporting further research and evaluation in clinical studies.


Subject(s)
Antigens, Viral/isolation & purification , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Point-of-Care Testing , SARS-CoV-2/isolation & purification , Animals , COVID-19/immunology , COVID-19/virology , COVID-19 Serological Testing/instrumentation , Chlorocebus aethiops , Coronavirus NL63, Human/immunology , Coronavirus NL63, Human/isolation & purification , Diagnosis, Differential , High-Throughput Screening Assays/instrumentation , High-Throughput Screening Assays/methods , Humans , Influenza A Virus, H1N1 Subtype/immunology , Influenza A Virus, H1N1 Subtype/isolation & purification , Ion Mobility Spectrometry , Proof of Concept Study , SARS-CoV-2/immunology , Vero Cells
12.
Nat Commun ; 12(1): 4586, 2021 07 28.
Article in English | MEDLINE | ID: covidwho-1387355

ABSTRACT

Heterogeneous immunoassays such as ELISA have become indispensable in modern bioanalysis, yet translation into point-of-care assays is hindered by their dependence on external calibration and multiple washing and incubation steps. Here, we introduce RAPPID (Ratiometric Plug-and-Play Immunodiagnostics), a mix-and-measure homogeneous immunoassay platform that combines highly specific antibody-based detection with a ratiometric bioluminescent readout. The concept entails analyte-induced complementation of split NanoLuc luciferase fragments, photoconjugated to an antibody sandwich pair via protein G adapters. Introduction of a calibrator luciferase provides a robust ratiometric signal that allows direct in-sample calibration and quantitative measurements in complex media such as blood plasma. We developed RAPPID sensors that allow low-picomolar detection of several protein biomarkers, anti-drug antibodies, therapeutic antibodies, and both SARS-CoV-2 spike protein and anti-SARS-CoV-2 antibodies. With its easy-to-implement standardized workflow, RAPPID provides an attractive, fast, and low-cost alternative to traditional immunoassays, in an academic setting, in clinical laboratories, and for point-of-care applications.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoassay/standards , Luminescent Measurements/standards , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/blood , COVID-19/immunology , COVID-19/virology , COVID-19 Serological Testing/instrumentation , Calibration , GTP-Binding Proteins/chemistry , Genes, Reporter , Humans , Immunoconjugates/chemistry , Limit of Detection , Luciferases/genetics , Luciferases/metabolism , Point-of-Care Testing , SARS-CoV-2/genetics
13.
PLoS One ; 16(9): e0256566, 2021.
Article in English | MEDLINE | ID: covidwho-1381283

ABSTRACT

BACKGROUND: Adequate testing is critically important for control of the SARS-CoV-2 pandemic. Antibody testing is an option for case management and epidemiologic studies, with high specificity and variable sensitivity. However, characteristics of local populations may affect performance of these tests. For this reason, the National Institute of Health (INS) and regulatory agencies in Colombia require verification of diagnostic accuracy of tests introduced to the Colombian market. METHODS: We conducted a validation study of the Abbott SARS-CoV-2 test for qualitative detection of IgG using the Abbott Architect i2000SR. Participants and retrospective samples were included from patients with suspected SARS-CoV-2 infection, age ≥18 years, and ≥8 days elapsed since initiation of symptoms. Pre-pandemic plasma samples (taken before October 2019) were used as controls. We estimated the sensitivity, specificity and agreement (kappa) of the Abbott IgG test compared to the gold standard (RT-PCR). RESULTS: The overall sensitivity was 83.1% (95% CI: 75.4-100). Sensitivity among patients with ≥14 days since the start of symptoms was 85.7%, reaching 88% in samples collected from patients with COVID-19 symptoms onset >60 days. Specificity was 100% and the kappa index of agreement was 0.804 (95% CI: 0.642-0.965). CONCLUSIONS: Our findings show high sensitivity and specificity of the Abbott IgG test in a Colombian population, which meet the criteria set by the Colombian INS to aid in the diagnosis of COVID-19. Data from our patient groups also suggest that IgG response is detectable in a high proportion of individuals (88.1%) during the first two months following onset of symptoms.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/instrumentation , COVID-19/blood , Immunoglobulin G/blood , Pandemics , SARS-CoV-2/metabolism , Adult , Aged , COVID-19/epidemiology , Colombia/epidemiology , Female , Humans , Male , Middle Aged , Prospective Studies , Retrospective Studies , Sensitivity and Specificity
15.
J Immunol Methods ; 496: 113096, 2021 09.
Article in English | MEDLINE | ID: covidwho-1349521

ABSTRACT

Serology or antibody tests for COVID-19 are designed to detect antibodies (mainly Immunoglobulin M (IgM) and Immunoglobulin G (IgG) produced in response to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS CoV-2) infection. In this study, 30 lateral flow immunoassays were tested using serum or plasma from patients with confirmed SARS CoV-2 infection. Negative serological controls were accessed from a well-characterised bank of sera which were stored prior to February 2020. Operational characteristics and ease of use of the assays are reported. 4/30 (13%) of kits (Zheihang Orient Gene COVID-19 IgG/IgM, Genrui Novel Coronavirus (2019-nCoV) IgG/IgM, Biosynex COVID-19 BSS IgG/IgM, Boson Biotech 2019-nCoV IgG/IgM) were recommended for SAHPRA approval based on kit sensitivity. Of these, only the Orientgene was recommended by SAHPRA in August 2020 for use within the approved national testing algorithm while the remaining three received limited authorization for evaluation. All kits evaluated work on the same basic principle of immunochromatography with minor differences noted in the shape and colour of cartridges, the amount of specimen volume required and the test duration. Performance of the lateral flow tests were similar to sensitivities and specificities reported in other studies. The cassettes of the majority of kits evaluated (90%) detected both IgG and IgM. Only 23% of kits evaluated contained all consumables required for point-of-care testing. The study highlights the need for thorough investigation of kits prior to implementation.


Subject(s)
Antibodies, Viral/isolation & purification , COVID-19 Serological Testing/instrumentation , COVID-19/diagnosis , Immunoassay/instrumentation , Reagent Kits, Diagnostic/statistics & numerical data , Antibodies, Viral/blood , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/immunology , COVID-19/virology , COVID-19 Nucleic Acid Testing/statistics & numerical data , COVID-19 Serological Testing/statistics & numerical data , Humans , Immunoassay/statistics & numerical data , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunoglobulin G/isolation & purification , Immunoglobulin M/blood , Immunoglobulin M/immunology , Immunoglobulin M/isolation & purification , Point-of-Care Testing/statistics & numerical data , RNA, Viral/blood , RNA, Viral/isolation & purification , SARS-CoV-2/genetics , SARS-CoV-2/immunology , SARS-CoV-2/isolation & purification , Sensitivity and Specificity
16.
J Clin Lab Anal ; 35(9): e23921, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1347406

ABSTRACT

BACKGROUND: SARS-CoV-2 pandemic is currently ongoing, meanwhile vaccinations are rapidly underway in some countries. The quantitative immunoassays detecting antibodies against spike antigen of SARS-CoV-2 have been developed based on the findings that they have a better correlation with the neutralizing antibody. METHODS: The performances of the Abbott Architect SARS-CoV-2 IgG II Quant, DiaSorin LIAISON SARS-CoV-2 TrimericS IgG, and Roche Elecsys anti-SARS-CoV-2 S were evaluated on 173 sera from 126 SARS-CoV-2 patients and 151 pre-pandemic sera. Their correlations with GenScript cPass SARS-CoV-2 Neutralization Antibody Detection Kit were also analyzed on 173 sera from 126 SARS-CoV-2 patients. RESULTS: Architect SARS-CoV-2 IgG II Quant and Elecsys anti-SARS-CoV-2 S showed the highest overall sensitivity (96.0%), followed by LIAISON SARS-CoV-2 TrimericS IgG (93.6%). The specificities of Elecsys anti-SARS-CoV-2 S and LIAISON SARS-CoV-2 TrimericS IgG were 100.0%, followed by Architect SARS-CoV-2 IgG II Quant (99.3%). Regarding the correlation with cPass neutralization antibody assay, LIAISON SARS-CoV-2 TrimericS IgG showed the best correlation (Spearman rho = 0.88), followed by Architect SARS-CoV-2 IgG II Quant and Elecsys anti-SARS-CoV-2 S (all rho = 0.87). CONCLUSIONS: The three automated quantitative immunoassays showed good diagnostic performance and strong correlations with neutralization antibodies. These assays will be useful in diagnostic assistance, evaluating the response to vaccination, and the assessment of herd immunity in the future.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/virology , Immunoassay/methods , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Antibodies, Neutralizing/blood , COVID-19 Serological Testing/instrumentation , Humans , Immunoglobulin G/blood , Neutralization Tests , ROC Curve , Reproducibility of Results , Sensitivity and Specificity , Serologic Tests
17.
Viruses ; 13(8)2021 07 30.
Article in English | MEDLINE | ID: covidwho-1335234

ABSTRACT

The development of rapid serological detection methods re urgently needed for determination of neutralizing antibodies in sera. In this study, four rapid methods (ACE2-RBD inhibition assay, S1-IgG detection, RBD-IgG detection, and N-IgG detection) were established and evaluated based on chemiluminescence technology. For the first time, a broadly neutralizing antibody with high affinity was used as a standard for the quantitative detection of SARS-CoV-2 specific neutralizing antibodies in human sera. Sera from COVID-19 convalescent patients (N = 119), vaccinated donors (N = 86), and healthy donors (N = 299) confirmed by microneutralization test (MNT) were used to evaluate the above methods. The result showed that the ACE2-RBD inhibition assay calculated with either ACE2-RBD binding inhibition percentage rate or ACE2-RBD inhibiting antibody concentration were strongly correlated with MNT (r ≥ 0.78, p < 0.0001) and also highly consistent with MNT (Kappa Value ≥ 0.94, p < 0.01). There was also a strong correlation between the two evaluation indices (r ≥ 0.99, p < 0.0001). Meanwhile, S1-IgG and RBD-IgG quantitative detection were also significantly correlated with MNT (r ≥ 0.73, p < 0.0001), and both methods were highly correlated with each other (r ≥ 0.95, p < 0.0001). However, the concentration of N-IgG antibodies showed a lower correlation with the MNT results (r < 0.49, p < 0.0001). The diagnostic assays presented here could be used for the evaluation of SARS-CoV-2 vaccine immunization effect and serological diagnosis of COVID-19 patients, and could also have guiding significance for establishing other rapid serological methods to surrogate neutralization tests for SARS-CoV-2.


Subject(s)
Antibodies, Neutralizing/blood , Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19 Vaccines/immunology , COVID-19/virology , Immunoassay/methods , Luminescent Measurements/methods , SARS-CoV-2/immunology , COVID-19/blood , COVID-19/immunology , COVID-19/prevention & control , COVID-19 Serological Testing/instrumentation , COVID-19 Vaccines/administration & dosage , Humans , SARS-CoV-2/genetics , Vaccination
18.
Am J Trop Med Hyg ; 105(2): 378-386, 2021 Jun 28.
Article in English | MEDLINE | ID: covidwho-1285448

ABSTRACT

Antibody tests can be tools for detecting current or past severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2 [coronavirus disease 2019 (COVID-19)]) infections. Independent test evaluations are needed to document the performance with different sample sets. We evaluated six lateral flow assays (LFAs) and two laboratory-based tests (EUROIMMUN-SARS-CoV-2 ELISA and Abbott-Architect-SARS-CoV-2-IgG). We tested 210 plasma samples from 89 patients diagnosed with acute COVID-19. These samples were collected at different time points after the onset of symptoms. In addition, 80 convalescent plasma samples, and 168 pre-pandemic samples collected from adults in the United States and in Africa were tested. LFA performance varied widely, and some tests with high sensitivity had low specificity. LFA sensitivities were low (18.8-40.6%) for samples collected 0 to 3 days after symptom onset, and were greater (80.3-96.4%) for samples collected > 14 days after symptom onset. These results are similar to those obtained by ELISA (15.6% and 89.1%) and chemiluminescent microparticle assay (21.4% and 93.1%). The range of test specificity was between 82.7% and 97%. The combined use of two LFAs can increase specificity to more than 99% without a major loss of sensitivity. Because of suboptimal sensitivity with early COVID-19 samples and background reactivity with some pre-pandemic samples, none of the evaluated tests alone is reliable enough for definitive diagnosis of COVID-19 infection. However, antibody testing may be useful for assessing the status of the epidemic or vaccination campaign. Some of the LFAs had sensitivities and specificities that were comparable to those of more expensive laboratory tests, and these may be useful for seroprevalence surveys in resource-limited settings.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/standards , COVID-19/diagnosis , Immunoassay/standards , Reagent Kits, Diagnostic/standards , SARS-CoV-2/immunology , Africa , COVID-19/blood , COVID-19/immunology , COVID-19 Serological Testing/instrumentation , COVID-19 Serological Testing/methods , Humans , Immunoassay/instrumentation , Immunoassay/methods , Immunoglobulin G/blood , Immunoglobulin M/blood , Retrospective Studies , Sensitivity and Specificity
19.
Sci Adv ; 7(26)2021 06.
Article in English | MEDLINE | ID: covidwho-1282047

ABSTRACT

Highly sensitive, specific, and point-of-care (POC) serological assays are an essential tool to manage coronavirus disease 2019 (COVID-19). Here, we report on a microfluidic POC test that can profile the antibody response against multiple severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens-spike S1 (S1), nucleocapsid (N), and the receptor binding domain (RBD)-simultaneously from 60 µl of blood, plasma, or serum. We assessed the levels of antibodies in plasma samples from 31 individuals (with longitudinal sampling) with severe COVID-19, 41 healthy individuals, and 18 individuals with seasonal coronavirus infections. This POC assay achieved high sensitivity and specificity, tracked seroconversion, and showed good concordance with a live virus microneutralization assay. We can also detect a prognostic biomarker of severity, IP-10 (interferon-γ-induced protein 10), on the same chip. Because our test requires minimal user intervention and is read by a handheld detector, it can be globally deployed to combat COVID-19.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , Point-of-Care Testing , SARS-CoV-2/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/virology , COVID-19 Serological Testing/instrumentation , Humans , Reproducibility of Results , SARS-CoV-2/metabolism , SARS-CoV-2/physiology , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/immunology , Spike Glycoprotein, Coronavirus/metabolism
20.
Diagn Microbiol Infect Dis ; 101(1): 115425, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1230427

ABSTRACT

The COVID-19 pandemic led to development of numerous serologic tests. To obviate the need for phlebotomy services, we validated dried blood spots (DBS) for anti-SARS-CoV-2 serologic testing. Immunoglobulins were extracted from 3 mm DBS punches and the extracts were analyzed using the Euroimmun anti-SARS-CoV-2 IgG ELISA. Various pre-analytical factors were studied. Results were favorable for DBS stored for at least 67 days at or below 37°C. Comparison between paired serum and DBS specimens tested by the Euroimmun ELISA showed 96.8% and 81.3% positive and negative agreement, respectively, indicating that confirmatory testing of positive Euroimmun results on DBS extracts is necessary to achieve clinical accuracy. Our findings suggest that any SARS-CoV-2 antibody assay that requires pre-dilution of serum is amenable to DBS as an alternate specimen type that is relatively low cost, self-collectable, stable, can be shipped by standard mail and could be used to establish the seroprevalence of large populations.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing , COVID-19/diagnosis , Dried Blood Spot Testing , Immunoglobulin G/blood , SARS-CoV-2/isolation & purification , COVID-19 Serological Testing/instrumentation , Dried Blood Spot Testing/instrumentation , Enzyme-Linked Immunosorbent Assay , Humans , SARS-CoV-2/immunology , Sensitivity and Specificity , Specimen Handling